ADC SNR, ENOB and SFDR calculator

Type the bits and SINAD from an ADC data sheet to get the ENOB, the ideal SNR, the noise density and the jitter limit.

Type SINAD (or SNR) to get the ENOB, or an ENOB to get the SINAD back.

Empty = the whole band. A narrower band gives processing gain.
ENOB12.00 bits
Ideal SNR86.04 dB
Noise density−151.0 dBFS/Hz
Jitter SNR84.04 dB
    Ideal converter numbers for 8 to 24 bits, with your sample rate, full scale and input frequency
    BitsIdeal SNRLSBNoise densityJitter limit

    How to use the ENOB calculator

    1. Type the converter's bits and its SINAD from the data sheet; the ENOB appears at once. Type an ENOB instead to get the SINAD back.
    2. If the data sheet measured with a tone below full scale, for example at −1 dBFS, type −1 in Test signal level.
    3. Open Noise, Jitter or SFDR and THD for the sample rate, clock and spurs. The table lists 8 to 24 bits with your numbers.

    Worked example: SINAD 74 dB is 12 bits

    Perfect 14-bit This ADC (SINAD) In a 1 MHz band Jitter, 100 fs 86.0 dB · 14 bits 74.0 dB · 12.0 bits 91.0 dB · 14.8 bits 84.0 dB limit 050100 dB
    Every 6.02 dB is one bit. Noise and distortion take 12 dB, 2 bits, from this 14-bit ADC; a narrow band wins some back.

    A 14-bit ADC data sheet lists a SINAD of 74 dB. ENOB = (74 − 1.76) ÷ 6.02 = 72.24 ÷ 6.02 = 12.0 bits. A perfect 14-bit converter would have 6.02 × 14 + 1.76 = 86.04 dB, so noise and distortion cost this part 2 bits. If the test tone was at −1 dBFS, add the missing 1 dB first: (74 − 1.76 + 1) ÷ 6.02 = 12.17 bits.

    Run it at 100 MS/s and the noise spreads over the 50 MHz Nyquist band: −74 − 10 × log10(50,000,000) = −151.0 dBFS/Hz. If your signal is only 1 MHz wide, a digital filter keeps 1/50 of that noise, a processing gain of 17.0 dB: 91.0 dB in the band, worth 14.8 bits. With a 2 V p-p full scale on 50 Ω (+10 dBm) the noise density is −141.0 dBm/Hz, and the ADC behaves like a 33.0 dB noise figure. A clock with 100 fs of jitter at a 100 MHz input sets an 84.04 dB limit and pulls the total from 74 to 73.59 dB.

    Use cases

    Compare ADC datasheets

    Two 100 MS/s ADCs: a 14-bit part with 72.5 dB SINAD at a 70 MHz input, and a 12-bit part with 70.0 dB. On paper the first has two more bits; in ENOB it is 11.75 against 11.34, less than half a bit apart. Compare them at the same input frequency and level, because SINAD falls as the input frequency rises (clock jitter is one reason), and check whether each figure was measured at −1 dBFS.

    Audio interface specs

    An interface with 24-bit converters lists 114 dB of dynamic range and THD+N of −100 dB. 114 dB is worth 18.6 bits and 100 dB of SINAD is 16.3 bits, which is why no real interface comes near the 146 dB of a perfect 24-bit converter. A-weighted figures usually read a few dB better than unweighted ones, so compare like with like. To measure the distortion of your own gear, use the THD analyzer.

    SDR dynamic range

    An SDR that streams 8-bit I/Q samples at 2.4 MS/s has an ideal SNR of 49.9 dB across the 2.4 MHz it shows. Choose I/Q in the Noise tab and type a 12.5 kHz signal bandwidth: the processing gain is 10 × log10(2.4 MHz ÷ 12.5 kHz) = 22.8 dB, so inside a narrow FM channel the floor drops to give up to 72.8 dB, about 11.8 bits' worth, in theory. Real receivers add their own noise, so expect less. A strong station also makes spurs; the SFDR tab shows whether a spur rises above the FFT noise floor.

    Formulas

    • ENOB = (SINAD − 1.76 + C) ÷ 6.02, where C is how many dB the test signal was below full scale (1 for −1 dBFS).
    • Ideal SNR = 6.02 × N + 1.76 dB for a full-scale sine and quantisation noise spread over the Nyquist band.
    • SINAD from SNR and THD = −10 × log10(10−SNR/10 + 10THD/10), with THD in dBc (a negative number).
    • Noise density = −SNR − 10 × log10(band) dBFS/Hz, with band = fs ÷ 2 for real samples and fs for I/Q. Processing gain = 10 × log10(band ÷ signal bandwidth).
    • ADC noise figure = full scale (dBm) + 174 − SNR − 10 × log10(band).
    • Jitter SNR = −20 × log10(2π × fin × tj). Noise from different causes adds as power.
    • FFT noise floor per bin = −SNR − 10 × log10(M ÷ 2) for an M-point FFT with no window; SFDR = signal − largest spur.

    Limits

    These are the textbook relations for a sine-wave test. Real converters change with input frequency, level, temperature and sample rate, so the test conditions in the data sheet matter as much as the number. The noise density and noise figure assume the noise is spread evenly across the band. That is close for most fast ADCs, but not for sigma-delta audio converters, which push their noise out of the audio band. To get the clock jitter from a phase noise curve, use the jitter calculator. All RF calculators are on the RF tools page.

    FAQ

    What is ENOB?

    Effective number of bits: how many bits a real converter is worth once noise and distortion are counted.

    How do I get ENOB from SINAD?

    ENOB = (SINAD − 1.76) ÷ 6.02. A SINAD of 74 dB gives 12.0 bits.

    What SNR does a perfect 16-bit converter have?

    About 98 dB: 6.02 × 16 + 1.76 = 98.08 dB.

    Why is my 24-bit interface only 19 bits?

    Analog noise limits it; around 115–120 dB SNR is excellent in practice, which is about 19 bits.

    Written and tested by the SpectrumAnalyzer.app team · Last checked

    How we tested: Checked by hand: SINAD 74 dB gives ENOB 12.00 bits (12.17 when measured at −1 dBFS), 16 bits give 98.08 dB, and 100 fs at a 100 MHz input limits SNR to 84.04 dB.