Cascaded noise figure calculator (Friis)
List your receiver stages in signal order with their gain and noise figure to get the total noise figure, noise temperature, sensitivity and each stage's share.
Stages, in signal order (antenna first)
A cable or attenuator has a gain of minus its loss and a noise figure equal to its loss (at room temperature).
Stage 1 (LNA) sets 74 % of the added noise.
Share of the added noise
- Total noise figure 1.30 dB (noise factor 1.349), noise temperature 101.2 K.
- Noise floor in 1 MHz: −112.7 dBm at the input, −99.7 dBm at the output (after 13.0 dB of gain).
- Sensitivity for 10.0 dB SNR: −102.7 dBm (−174 dBm/Hz + 60.0 dB for the bandwidth + 1.30 dB NF + 10.0 dB SNR).
- In reverse order the same stages would give 10.53 dB: the order matters.
How to use the noise figure calculator
- List the stages in the order the signal passes through them, starting at the antenna. Type a name, the gain in dB (a loss is a negative gain) and the noise figure in dB from each data sheet.
- Press Add stage for amplifiers, mixers and filters, or Add cable or attenuator for a passive loss. Drag the ⠿ handle, or use the arrow buttons, to change the order.
- Read the total noise figure, gain and noise temperature, and the bar chart showing which stage adds the most noise. Add the bandwidth and the SNR your signal needs for the sensitivity.
Worked example: LNA and mixer
First turn every decibel into a plain ratio. The LNA's 1 dB noise figure is a noise factor of 100.1 = 1.259, and its 20 dB gain is 100. The mixer's 10 dB noise figure is a factor of 10.
Friis: F = 1.259 + (10 − 1) ÷ 100 = 1.259 + 0.090 = 1.349. Back in decibels that is 10 × log10(1.349) = 1.30 dB. The total gain is 20 − 7 = 13 dB, and the noise temperature is 290 × 0.349 = 101 K.
The bars split the added noise (F − 1 = 0.349) between the stages: the LNA brings 0.259, or 74 %, and the mixer only 0.090, or 26 %, although its own noise figure is ten times worse. With a 1 MHz bandwidth and a wanted SNR of 10 dB, the sensitivity is −174 + 60 + 1.3 + 10 = −102.7 dBm.
Why the first stage matters most
Every stage adds its own noise, but the gain in front of it divides that noise before it counts. The first stage has nothing in front, so its noise counts in full. Swap the two stages of the example and the total jumps from 1.30 dB to 10.53 dB: the mixer now comes first with its 10 dB, and its 7 dB of loss even makes the LNA's noise count more.
Loss works the same way. Put a cable with 2 dB of loss between the antenna and the LNA and the total becomes 3.30 dB, exactly 2 dB worse. Put the same cable after the LNA and the total is only 1.48 dB. That is why a good LNA sits right at the antenna, as on a satellite dish, and the long cable comes after it. Try it: press Add cable or attenuator, then drag the new stage to the top and back.
More gain in the first stage helps only up to a point. With 10 dB of LNA gain the example gives 3.34 dB, with 20 dB it gives 1.30 dB, and with 30 dB 1.03 dB, already close to the LNA's own 1 dB. Past that, extra gain buys almost nothing and makes the later stages easier to overload, so designers stop once the first stage's gain is well above the next stage's noise figure.
Formula
- Noise factor from noise figure: F = 10NF / 10; gain ratio: G = 10gain / 10.
- Friis: Ftotal = F1 + (F2 − 1) ÷ G1 + (F3 − 1) ÷ (G1 × G2) + …, and NFtotal = 10 × log10(Ftotal).
- Each stage's share is its own term, (Fn − 1) ÷ (G1 × … × Gn−1), divided by Ftotal − 1.
- Noise temperature: T = 290 × (F − 1) kelvin.
- Sensitivity: −174 dBm/Hz + 10 × log10(bandwidth in Hz) + NFtotal + SNR.
Limits
Gains and noise figures change with frequency, so use data sheet values for the frequency you care about. For a filter or any other passive part, the noise figure equals its insertion loss, and a passive mixer's noise figure is close to its conversion loss. The formula assumes every stage is matched to the next and that each stage works well below its compression point: a strong signal that pushes an LNA into distortion is a different problem, covered by intercept points instead. The sensitivity line assumes a source at room temperature (290 K); an antenna pointed at a cold sky sees less noise, one pointed at the ground or a city sees more. To turn the result into a spectrum analyzer's floor, use the noise floor calculator; for the converter at the end of an SDR, see ADC SNR. More tools are on the RF tools page.
FAQ
What is the Friis formula?
F_total = F1 + (F2 − 1)/G1 + (F3 − 1)/(G1·G2) …, with values as linear ratios.
Why put the LNA first?
Its gain divides the noise of every later stage, so the first stage sets most of the total.
What is noise temperature?
Another way to state noise: T = 290 × (F − 1) kelvin.
Does a lossy cable before the LNA hurt?
Yes, its loss adds directly to the noise figure.